E2S AL100H Alarm Horn Sounder and LED Beacon
The E2S AL100H features the 104dB(A) E2S A100 Alarm Horn Sounder combined with the E2S L101H high output LED Beacon.
The E2S AL100H features the 104dB(A) E2S A100 Alarm Horn Sounder combined with the E2S L101H high output LED Beacon. The compact, robust housing is ideal for all general signalling applications such as fire, security and process control.
Features
High output LED array
Automatic synchronisation on multi-sounder system
Continuously rated
Stainless steel fixings
Unit can be mounted using external lugs or internal BESA compatible fixing positions
Duplicate cable terminations (in & out for daisy-chain installations)
Tropicalisation available on request
Available with custom tone configurations and frequencies
‘Programmable’ version available:
– 45 alarm tones
– 4 remotely selectable stages
– Any tone can be assigned to any stage
– User configurable continuous frequency tone.
Maximum output |
[101dB(A) @ 10ft/3m +/-3dB] ,110dB(A) @ 1 m +/-3dB |
---|---|
Nominal output |
[93dB(A) @ 10ft/3m +/-3dB] ,102dB(A) @ 1m +/-3dB |
No. of tones |
64 (UKOOA / PFEER compliant) |
No. of stages |
4 |
Volume control |
-12dB(A) tone dependent |
Effective range |
38m/124ft @ 1KHz |
In rush |
636mA within 4.0ms @ 24Vdc |
Stage switching |
Negative (common positive) |
Light Source |
High intensity L.E.D. array. ,18 x Cree SMT White LED |
High Power Steady |
180 cd – measured ref. to I.E.S. |
1Hz Flash cd |
113 cd – measured ref. to I.E.S. |
LED life |
60,000 hours |
Settings |
1. High Power Steady ,5. Double Flash ,6. Triple Flash ,8. Temporal Pattern Flash ,2. Blinking – 425ms ON 75ms OFF ,3. 1.0Hz (60 fpm) – 200ms ON 800ms OFF ,4. 1.33Hz (80fpm) – 150ms ON 600ms OFF ,7. 2.0Hz (120fpm) – 125ms ON 375ms OFF |
Safety Integrity Level |
SIL1 and SIL2 Route 2H IEC61508 (2010) |
Ingress protection |
IP66 Type 3R/13 |
Enclosure |
High impact UL94 V0 & 5VA FR ABS/PC |
Lens colour filter |
Field replaceable UV stable PC |
Terminals |
0.5 – 2.5mm2 (20-14 AWG) |
Line monitoring |
Diode polarized for use in supervised circuits |
Operating temperature |
-40 to +66°C [-40° to +151°F] |
Storage temperature |
-40 to +70°C [-40° to +158°F] |
Relative Humidity |
95% at 20°C [68°F] |
Vibration test |
35Hz for a duration 4Hr (UL464/UL1638) |
Jarring test |
3ft/lb Energy (UL464/UL1638) |
Impact test |
3x 5lb (UL464/UL1638) |
MTBF DC |
113.31 years / 992,555 hours – MIL 217 |
MTBF AC |
75.37 years / 660,283 hours – MIL 217 |
Weight DC |
0.46kg / 1.01lbs |
Weight AC |
0.57kg / 1.25lbs |
Related products
Need some help with your project?
Send an enquiry or contact us directly and we will try our best to help you.